3 Start-Up
3.14 Configuring an OEM-valve list
Language-
dependent texts
Language-
dependent system
texts
Language-
dependent OEM
texts
3-96
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Any language-dependent texts can be inserted in the OEM valve list. These all
start with $T.
Syntax:
$T<X> (no dash dot)
In this case, <X> refers to a text in the language-dependent
text files
(see also language-dependent OEM texts)
Subheadings can also be inserted in the OEM valve list by adding the instruc-
tion "$L=<beliebiger Text>;" at the beginning of a line. $T<X> can be used to
insert other language-dependent texts within this optional text instruction.
The following language-dependent texts are predefined by the system and can
be used in OEM valve lists.
$T1=Order No.;
$T2=Name;
$T3=Rated flow;
$T4=Knee-point voltage;
$T5=Rated flow A:B;
$T6=Code;
$T7=" Knee";
$T8=" Linear";
$T9=Company;
$T10=Unlisted valve;
$T11=l/min;
Language-dependent OEM display texts are stored in directory \oem\language
in files \ibdrv_<SPRACHE>.ini
< SPRACHE > stands for the appropriate language code. This file would be
named ibdrv_gr.ini for German. The codes for all languages installed in a sys-
tem are listed in file \mmc2\mmc.ini, section [LANGUAGE], entry LanguageL-
ist. Language-dependent OEM text files must be formatted as follows:
[TEXT]
$T<X>=<beliebiger Text>;
:<X> is any number w1000 and v32767, that must only occur once.
The number range from 1 to 999 is reserved for the system.