5 Hardware Drive Functions
5.1 Overview of interfaces
5.1.1
Measuring system
Measuring
systems
5-176
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
One position encoder for each axis can be evaluated on the module.
S
X101:
Axis 1
S
X102:
Axis 2
The measuring system must always be inserted in the connector of the associ-
ated axis.
For further information, please see Section 7.1.
Table 5-1
PlugX101, X102; in each case15-pole subminiature D plug (two-tier)
Pin
X101
X102
1
PENC0
PENC2
2
M
M
3
AP0
AP2
4
AN0
AN2
5
BMIDAT0
BMIDAT2
6
BP0
BP2
7
BN0
BN2
8
XBMIDAT0
XBMIDAT2
9
PSENSE0
PSENSE2
10
RP0
RP2
11
MSENSE0
MSENSE2
12
RN0
RN2
13
M
M
14
BMICLK0
BMICLK2
15
XBMICLK0
XBMICLK2
Function
Encoder power supply
Encoder power supply ground
Incremental signal A
Inverse incremental signal A
Data signal, EnDat interface
Incremental signal B
Inverse incremental signal B
Inverse data signal, EnDat interface
Remote Sense encoder power supply (P)
Incremental signal R
Remote Sense encoder power supply (M)
Inverse incremental signal R
Ground (for internal shields)
Clock signal, EnDat interface
Inverse clock signal, EnDat interface
Siemens AG 2000. All rights reserved
02.99