Monitoring Functions - Siemens SINUMERIK 840D Description Of Functions

Hla module
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

4 Firmware Drive Functions
4.13 Mounting functions
4.13

Monitoring functions

4.13.1
Alarms
Power On alarms
5600
ALARM_MASK_POWER_ON
Concealable alarms (Power On)
Bit 4: "Measuring circuit measuring system"
Bit 5: Measuring circuit absolute track
Bit 8: "Zero marker error"
Unit:
Default:
HEX
0
5612
ALARM_REACTION_POWER_ON
Config. shutdown reaction to PO alarms
Bit 0= 0: No enable signal cancellation in response to
internal errors
1: Enable signal cancellation in response to internal
errors
Unit:
Default:
HEX
0
5731
CL1_PO_IMAGE
Image ZK1_PO register
Unit:
Default:
HEX
0
RESET alarms
5601
ALARM_MASK_RESET
Concealable alarms (Reset)
Bit 7:
"Valve controller not reacting"
Bit 8:
"Velocity controller at limit"
Bit 9:
"Encoder limit frequency exceeded"
Bit 10:
"Piston position negative"
Bit 11:
"Pressure measurement failure"
Bit 12:
"Force limitation OFF"
Unit:
Default:
HEX
0
5613
ALARM_REACTION_RESET
Config. shutdown reaction to RESET alarms
Bit 0= 0: No enable signal cancellation in response to
configuration errors
1: Enable signal cancellation in response to
configuration errors
Unit:
Default:
HEX
0
4-150
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Minimum:
Maximum:
0
FFFF
Minimum:
Maximum:
0
FFFF
Minimum:
Maximum:
0
FFFF
MD 5600: ALARM_MASK_POWER_ON can be set to conceal Power On
alarms. If the relevant bit is set to 0, the corresponding error monitoring function
is active. If the bit=1, the error monitoring function is suppressed. The default
setting is "active" for all monitoring functions.
MD 5612: ALARM_REACTION_POWER_ON is set to configure switchover of
the relevant Power On alarm.
For alarm messages, see Chapter 6, numbers 300500...300599.
Minimum:
Maximum:
0
FFFF
Minimum:
Maximum:
0
FFFF
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
UNS.WORD
Immediately
 Siemens AG 2000. All rights reserved
02.99