4 Firmware Drive Functions
4.10 Position measuring system
Actual position
5040
PISTON_ZERO
Piston zero in relation to machine zero
Unit:
Default:
mm
0.0
4-142
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Minimum:
Maximum:
–1000000.0
100000.0
The offset between the piston zero (end stop at A end) and machine zero must
be set in MD 5040: PISTON_ZERO.
If the actual position is available in machine coordinates in the drive after the
reference point approach, it can be applied to calculate the piston position (e.g.
for adaptation).
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Siemens AG 2000. All rights reserved
02.99