02.99
300 754
Explanation
Reaction
Remedy
To continue
program
300 770
Explanation
Reaction
Remedy
To continue
program
300 799
Explanation
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Axis %1, drive %2 signal number var. signalling function invalid
%1 = NC axis number
%2 = drive number
The signal number for output of the appropriate signalling function is illegal. The
permissible signal number range starts at 0 and ends at 29.
NC not ready.
Switchover for entire channel via MD might be possible.
Channel not ready.
NC Stop in response to alarm.
NC Start disable.
The NC switches to follow-up mode.
Alarm is displayed.
Interface signals are set.
Please inform authorized personnel/service engineer.
Enter the correct signal number.
Cancel alarm in all channels by pressing RESET key. Restart the part program.
Axis %1, drive %2 format error
%1 = NC axis number
%2 = drive number
The calculated filter coefficients for a bandstop cannot be represented in the
internal format.
The alarm can be reconfigured in MD 11412: ALARM_REACTION_CHAN_NO-
READY (channel not ready).
NC not ready.
Switchover for entire channel via MD might be possible.
Channel not ready.
NC Stop in response to alarm.
NC Start disable.
The NC switches to follow-up mode.
Alarm is displayed.
Interface signals are set.
Please inform authorized personnel/service engineer.
Change the filter setting.
Troubleshooting for the exact error cause can be supported by Hotline staff. Call
SIEMENS AG, SIMODRIVE Hotline.
Cancel alarm in all channels by pressing RESET key. Restart the part program.
Axis %1, drive %2 save and boot necessary
%1 = NC axis number
%2 = drive number
After drive machine data have been modified, parameters need to be re-calcu-
lated. The calculation routine is started with softkey CALCULATE. After the con-
trol parameters have been calculated, the machine data must be saved and the
system powered up again.
The alarm can be reconfigured in MD 11412: ALARM_REACTION_CHAN_NO-
READY (channel not ready).