Siemens SINUMERIK 840D Description Of Functions page 124

Hla module
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

4 Firmware Drive Functions
4.4 Closed-loop force control
5265
FFW_FCTRL_FIL_1_DAMP [n]
PT2 damping for feedforward control filter 1
Unit:
Default:
0.7
5268
FFW_FCTRL_FIL_1_SUP_FREQ [n]
Blocking frequency of feedforward control filter 1
Unit:
Default:
Hz
3500.0
5269
FFW_FCTRL_FIL_1_BW [n]
Bandwidth of feedforward control filter 1
Unit:
Default:
Hz
500.0
5270
FFW_FCTRL_FIL_1_BW_NUM [n]
Numerator bandwidth feedforward control filter 1
Unit:
Default:
Hz
0.0
4-124
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
0...7 index of the parameter set
Minimum:
Maximum:
0.2
1.0
Input of damping for feedforward control filter 1 (PT2 low-pass) in force control-
ler.
0...7 index of the parameter set
Minimum:
Maximum:
10.0
7999.0
Input of blocking frequency for feedforward control filter 1 (band-stop) in force
controller.
0...7 index of the parameter set
Minimum:
Maximum:
5.0
7999.0
Input of –3 dB bandwidth for feedforward control filter 1 (band-stop) in force con-
troller.
0...7 index of the parameter set
Minimum:
Maximum:
0.0
7999.0
Input of numerator bandwidth for feedforward control filter 1 (damped band-
stop) in force controller.
Setting a value of 0 initializes the filter as an undamped band-stop. The value
set in MD 5270 must not exceed twice the value set in MD 5269.
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
Cross ref.: –
Relevant for:
Protection level:
HLA
3/3
Data type:
Effective:
FLOAT
Immediately
 Siemens AG 2000. All rights reserved
08.99
02.99

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611 digital

Table of Contents