Siemens SINUMERIK 840D Description Of Functions page 95

Hla module
Hide thumbs Also See for SINUMERIK 840D:
Table of Contents

Advertisement

02.99
Table 3-15
Meaning of individual columns
Col-
Description
umn in
OEM
OEM
valve
list
1
Valve code no.
2
Manufacturer's name
3
Order No.
4
Designation
5
Rated valve flow
6
Rated pressure drop of
valve
7
Rated voltage of valve
8
Valve knee-point voltage
9
Knee-point voltage of valve
10
Rated flow rate ratio be-
tween A and B ends of valve
11
Valve configuration
12
Natural frequency of valve
13
Valve damping
14
Rated valve flow for display
15
Valve knee-point voltage for
display
 Siemens AG 2000. All rights reserved
SINUMERIK 840D/SIMODRIVE 611 digital Descr. of Functions HLA Module (FBHLA) – 04.00 Edition
Column in
MMC dis-
play
play
7
VALVE_CODE
1
2
3
VALVE_NOMINAL_FLOW
VALVE_NOMINAL_PRESSSURE
VALVE_NOMINAL_VOLTAGE
VALVE_DUAL_GAIN_FLOW
VALVE_DUAL_GAIN_VOLTAGE
6
VALVE_FLOW_FACTOR_A_B
VALVE_CONFIGURATION
VALVE_NATURAL_FREQUENCY
VALVE_DAMPING
4
5
The valve code is entered in the first column and must be a number. Numbers 1
to 1000 are reserved for Siemens. Individual values are separated by commas.
Columns 1 and 2 are separated by an equals signal (=). Comments are pre-
ceded by a semicolon.
Different numeric formats may be used.
S
The following applies to the display (selection list) on the MMC:
The character strings used are identical to those stored in the INI file.
S
The following applies to writing machine data:
– Unless otherwise specified, the decimal format is always used. If the
number is followed by a capital B, it is interpreted as a binary number. If
a capital H is inserted after the number, it is interpreted as a hexadecimal
value.
– Floating-point numbers must be specified in US format (decimal
point=".") and WITHOUT the separator symbol for 1000s (",").
– The individual fields in this section can be left empty, i.e. they contain 2
commas one after the other or two blanks between the 2 commas.
Empty fields are not written to the drive, i.e. the default setting of the ma-
chine data is transferred unchanged. The number of blanks is optional.
3.14 Configuring an OEM-valve list
Reference to MD
Name
No.
5106
5107
5108
5109
5110
5111
5112
5113
5114
5115
3 Start-Up
Unit
[l/min]
[bar]
[V]
[%]
[%]
[Hz]
[l/min]
[%]
3-95