• Bit device setting
Set a number in a unit of 32 points at the start of the device.
The connection status for each input axis type is stored in the set devices as follows.
Offset
Item
+0
Servo input axis connecting information Axis 1
+1
Servo input axis connecting information Axis 2
to
to
+31
Servo input axis connecting information Axis 32
+32
Command generation axis connecting information Axis 1
+33
Command generation axis connecting information Axis 2
to
to
+63
Command generation axis connecting information Axis 32
+64
Synchronous encoder axis connecting information Axis 1
+65
Synchronous encoder axis connecting information Axis 2
to
to
+75
Synchronous encoder axis connecting information Axis 12
+76
Empty
to
+95
7 AUXILIARY AND APPLIED FUNCTIONS
158
7.10 Multiple CPU Advanced Synchronous Control