Mitsubishi Electric R32MTCPU Programming Manual page 128

Advanced synchronous control
Hide thumbs Also See for R32MTCPU:
Table of Contents

Advertisement

[Md.400] Current value after composite main shaft gear (D13600+30n, D13601+30n)
The current value after combining the main input and the sub input values going into the composite main shaft gear is stored
as an accumulative value.
Units are in position units of the main input axis. The unit is pulse if the main input axis is invalid. (Page 30 Servo input
axis position units, Page 37 Command generation axis position units, Page 51 Synchronous encoder axis position
units)
The current value after composite main shaft gear will be changed when the following operations are executed in the main
input axis during synchronous control.
Operation of main
Servo input axis
input axis (During
Absolute
synchronous
position
control start)
detection
system valid
Home position return
Change method (1)
Current value change
Change method (1)
*1
Speed control ()
Change method (1)
Fixed-pitch feed
Change method (1)
control
Speed/position
Change method (1)
*2
switching control
Connection to servo
Change method
amplifier
(2)
Connection to
synchronous encoder
*1 When it starts by turning OFF the "[Rq.1152] Feed current value update command (M3212+20n)" or "[Rq.347] Feed current value
update request command (M10972+20n)".
*2 When it starts by turning OFF the "[Rq.1152] Feed current value update command (M3212+20n)".
*3 When setting as a slave CPU synchronous encoder axis type (master CPU servo input axis, master CPU command generation axis,
master CPU synchronous encoder axis) in a Multiple CPU advanced synchronous control configuration.
■Change method (1)
The new current value after composite main shaft gear is calculated based on the current value of the main input axis.
Current value after composite main shaft gear=Main input direction of composite main shaft gear (Input +/Input -/No input
(0))Main input axis current value
■Change method (2)
The travel value of the main input axis from the last synchronous control session is reflected to the current value after
composite main shaft gear.
Current value after composite main shaft gear=Current value after composite main shaft gear at the last synchronous control
session+Main input direction of composite main shaft gear (Input +/Input -/No input (0))Amount of change of travel value of
main input axis from the last synchronous control session
[Md.401] Current value per cycle after main shaft gear (D13602+30n, D13603+30n)
The input travel value after the main shaft gear is stored within the range from 0 to (Cam axis length per cycle - 1). The unit is
in cam axis cycle units. (Page 114 Cam axis cycle units)
The value is restored according to "[Pr.460] Setting method of current value per cycle after main shaft gear (D15100+150n)"
when starting synchronous control. (Page 139 Current value per cycle after main shaft gear, current value per cycle after
auxiliary shaft gear when starting synchronous control)
6 SYNCHRONOUS CONTROL
126
6.7 Synchronous Control Monitor Data
Command
generation
Absolute
axis
position
detection
system invalid
Change
method (1)
Change
method (1)
Change
method (1)
Change method
(1)
Synchronous encoder axis
Incremental
Absolute
synchronous
synchronous
encoder
encoder
Change method (1)
Change method
Change method (2)
(1)
Synchronous
Multiple CPU
encoder via
advanced
device
synchronous
*3
control
Change method
(1)

Advertisement

Table of Contents
loading

This manual is also suitable for:

R16mtcpuMelsec iq-r series

Table of Contents