[ 806] CARD PRE-INSTALL

2 1 2 B
Allows the pre-programming of a card slot for a specific card type. A card inserted into a
system will not be recognized by the system until it is enabled using this MMC. Cards
installed using this MMC will not be assigned in the system numbering plan—you should
use MMC 724 to assign the desired directory numbers to extensions, trunks, ports or
miscellaneous functions.
When a card is removed and a different type card is inserted
If a card is removed and a different card is inserted, and this MMC is performed,
the memory associated with the previous card(e.g., key programming) will be
erased.
In case of OfficeServ 7100 system, when a previous card is UNI Board and a new
card is the same although a new UNI card has different modules compared to a
previous UNI card, it does not need to preinstall because the OfficeServ 7100
system automatically recognizes the change.
reset card function is only possible in BRI card.
D EFAULT DATA
8 9 5 B
NONE
A CTION
8 9 6 B
1) Press Transfer button and enter 806.
Display shows:
2) Enter cabinet number via dial keypad.(e.g., 1)
OR
Press Volume button to make selection and
press Right Soft button.
3) Enter slot number via dial keypad.(e.g., 6)
OR
Press Volume button to make selection and
press Right Soft button.
4) Dial 1 for YES to reset card or dial 0 for NO.
OR
2-306
In case of OfficeServ 7030 system,
DISPLAY
C:
1
– S:1
U
U
8 DLI 8 DLI
C:1–S:
1
U
U
8 DLI 8 DLI
C:1–S:6
16 DLI 16 DLI
C:1–S:6
RESET CARD ?