[ 502] STATION-WIDE TIMERS

1 3 1 B
Allows certain station timer values to be changed on a per-station basis or for all stations.
No
Item
0
NO ANS FWD
1
DTMF DUR.
2
F-DGT DELY
3
OFFHK SEL.
4
EFWD DELAY
5
CC RNG DLY
6
PING RING
C ONDITIONS
6 1 9 B
NONE
D EFAULT DATA
6 2 0 B
NO ANS FWD: 015 SEC
DTMF DUR: 100 MSEC
F-DGT DELY: 600 MSEC
OFFHK SEL: 008 SEC
EFWD DELAY: 010 SEC
CC RNG DLY: 010 SEC
PING RING : 000 SEC
Samsung Business Communications
This timer controls how long the station will ring before Forward on No
Answer takes place.(1-250 sec)
This timer governs the duration of DTMF digits which are transmitted to
an external VMS system port. This can be used when a VMS system fails
to recognise the default DTMF digit duration being transmitted from the
SLT port.(100-9900 ms)
This timer will be valuable for the system administrator to insert a suitable
delay before generating DTMF digits for In-Band integration.(100-
9900 ms)
This timer controls the grace period before placing an internal/external call
as programmed in MMC 306.(0-250 sec)
This timer controls the External Call Forward feature which will allow a
station to ring before the call is placed on external call forwarding.
(1-250 sec)
If a station does not answer an incoming call within this time, other
stations with a CC key for that station will ring.
This timer let the members of pickup group listen ping ring just one time. If
this value is 0, this function will not operate. And to allow this function, the
PINGRING SERVICE has to be enabled in MMC861. (0~250 sec)