C ONDITIONS
6 6 5 B
A station can be assigned to all station groups. A station group can normally
accommodate up to 99 members, but only up to 32 members if the RING MODE is
UNCONDITIONAL.
To enable off-hook ring for incoming calls to busy members, set OFFHOOK RING in
MMC 300, CUSTOMER ON/OFF PER STATION, to ON. Even in this case, however,
the off-hook ring is enabled only when the RING MODE is UNCONDITIONAL.
D EFAULT DATA
6 6 6 B
NORMAL GROUP
A CTION
6 6 7 B
1) Press Transfer button and enter 601.
Display shows:
2) Dial group number.(e.g., 505)
OR
Press Volume button to select group and
Press Right Soft button to move cursor.
3) Dial feature option number.(0-7, e.g., 0)
OR
Press Volume button to scroll options and press
Right Soft button to move cursor.
4) DIAL group type.(e.g., 1)
OR
Press Volume button to make selection and
press Left Soft button to move cursor to TYPE.
5) Dial feature option number.(0-6, e.g., 1)
OR
Press Volume button to scroll options and
press Right Soft button to move cursor.
6) Dial ring option.(0-2, e.g., 0)
OR
Press Volume button to make selection.
Press Left Soft button to move cursor
back to RING or press Right Soft button to
return to step 2.
Samsung Business Communications
CHAPTER 2. MMC Programming
DISPLAY
[501] STN.GROUP
TYPE:NORMAL GRP
[505] STN.GROUP
TYPE:NORMAL GRP
[505] STN GROUP
TYPE:VMAA GROUP
[505] STN GROUP
TYPE:VMAA GROUP
[505] STN GROUP
RING:DISTRIBUTE
[505] STN GROUP
RING:SEQUENTIAL