[ 702] TOLL DENY TABLE

1 6 1 B
Provides a way to make toll restriction(call barring) very easy and flexible. There are 500
entries allowed in the deny table and each entry index can be assigned to a class of service.
Each index can have up to 12 digits. With the use of wild cards(MMC 704, Assign Wild
Character), more flexibility can be built into toll restriction. Wild cards can be used
repeatedly in the dial string, limited only to what is allowed or denied in MMC 704.
Six toll levels, B to G, are programmable. Toll level A is set as 'unrestricted' by default and
toll level H is set as 'in-house only' by default.
D EFAULT DATA
7 1 8 B
ALL ENTRIES ARE SET TO 0
P ROGRAM BUTTONS
7 1 9 B
A
Used to enter wild card X
B
Used to enter wild card Y
C
Used to enter wild card Z
A CTION
7 2 0 B
1) Press Transfer button and enter 702.
Display shows:
2) Dial index number.(e.g., 005)
OR
Press Volume button to select index and press
Right Soft button to move cursor.
3) Enter toll pattern via dial keypad.(e.g., 212)
OR
Enter wild card(e.g., 21X) and press Right Soft
button to move cursor to COS options.
4) Press Volume button to move cursor along line until
under toll class mark.(e.g., E).
Enter a 1 for 'Yes' or 0 for 'No'.
Press Right Soft button to store and return to step 1.
OR
Press Left Soft button to return to step 2.
Samsung Business Communications
CHAPTER 2. MMC Programming
DISPLAY
DENY(
0
0 1):BCDEFG
U
U
:000000
DENY(005):BCDEFG
:000000
DENY(005):BCDEFG
212
:000000
DENY(005):BCDEFG
21X
:000000
DENY(001):BCDEFG
212
:000
1
0 0
U
U
2-213