ID
Level
1747
WARNING
On module <%s1>, an access error to <%s2> occurred.
Meaning: A communication error identified by %s2 occurred in the module indicated by %s1.
Action: If the communication error was temporary, this message is followed by a recovery
message (ID: 1748). In this case, no action is required. If the recovery message does not
appear in the log, contact your sales or service representative.
1748
Info
On module <%s1>, the access error to <%s2> has been corrected.
Meaning: The module indicated by %s1 recovered from the communication error identified
by %s2.
Action: No particular action is required.
1749
WARNING
On module <%s1>, POWER-ON is inhibited.
Meaning: The supply of power to the module indicated by %s1 is suppressed.
Potential causes are:
A configuration problem or invalid setting (such as an invalid hardware combination or
inadequate power supply).
Power supply is suppressed so that a maintenance task can take place (the module is under
maintenance or faulty).
Action: Resolve the problem causing the suppression. If the reason why the power supply is
being suppressed remains unclear, contact your sales or service representative.
174A
FAIL
On partition <%s>, An error occurred in FibreChannel card.
Meaning: An error occurred in a Fibre-channel card on the partition indicated by %s.
Action: Contact your sales or service representative.
174B
FAIL
On partition <%s>, A link down occurred in FibreChannel card.
Meaning: A linkdown occurred in a Fibre-channel card on the partition indicated by %s.
Action: Contact your sales or service representative.
174C
WARNING
On partition <%s>, A warning event occurred in FibreChannel card.
Meaning: A failure occurred in a Fibre-channel card on the partition indicated by %s.
Action: Contact your sales or service representative.
174D
Info
On partition <%s>, FibreChannel card has recovered from an error.
Meaning: A Fibre-channel card on the partition indicated by %s has recovered from an
error. .
Action: Contact your sales or service representative.
174F
FAIL
On partition <%s>, An error occurred in PCI card.
Meaning: An error occurred in a PCI card on the partition indicated by %s.
Action: Contact your sales or service representative.
1750
Info
On partition <%s1>, POWER-ON is starting.
Meaning: Power was turned on for the partition indicated by %s1.
Action: No particular action is required.
1751
Info
On partition <%s1>, RESET is occurring.
Meaning: The partition indicated by %s1 was reset.
Action: No particular action is required.
1752
Info
On partition <%s1>, POWER-OFF is starting.
Meaning: Power was shut off for the partition indicated by %s1.
Action: No particular action is required.
1753
Info
On partition <%s1>, an NMI was issued.
Meaning: A non-maskable interrupt (NMI) was issued in the partition indicated by %s1.
Action: No particular action is required.
1754
Info
On partition <%s1>, the panel button was pressed, and an NMI was
Message