Select a MAR log from the MAR log list, and the MAR log details are displayed.
+------------------------------+
| MARLOG (2009-03-09 10:13:39) |
+------------------------------+
-- CALL FACTOR INFORMATION --
Reason : 15
Impact : UU
-- RC INFORMATION --
EVENT
: 0000 02 D3EBB449 0100 04 1530 07A30001
RC
: 10 0100 10 15300000 07A30001
RC NAME
: IOH RUNTIME ERROR
COMMENT
: Uncorrectable IOH QPI failure
EventData2
bit[7]
:Logical Node ID
bit[3:0]:QPI Port#
1.Replace CPU Chip
(Suspected chip is specified by QPI Port#.)
2.Replace MB
Hit enter key.
(Enter)
-- FRU INFORMATION --
-- --------------- ------------------- ----------------- --------------
0 | UNIT
: SRV0
| PARTS NAME
: UNIT Not Inst
| ACTION
: RPL
| DRAWING_NO
:
-
-- --------------- ------------------- ----------------- --------------
1 | UNIT
: SRV0
| PARTS NAME
: UNIT Not Inst
| ACTION
: RPL
| DRAWING_NO
:
-
-- --------------- ------------------- ----------------- --------------
-- End of data --
Hit enter key.
Items of the detailed MAR log are described in the table below:
Description of
Item
item
Recorded time
Timestamp
and date (Local
time)
Message to show
Reason
a reason
Connection
Impact
trigger
| FRU MNEMONIC
| REV
| WEIGHT
| SERIAL NO
| FRU MNEMONIC
| REV
| WEIGHT
| SERIAL NO
Value
YYYY-MM-DD
YYYY: AD year; MM: month; DD: day;
hh:mm:ss
hh: hour; mm: minute; ss: second
XX
XX: Reason code
UU
Emergency: fix it quickly.
UE
Non-emergency: fix it the next day.
US
Non-emergency: fix it within a week.
UC
Non-emergency: the redundant
component.
PR
Protective maintenance request
512
: CPU0
:
-
: 60
:
-
: MB
:
-
: 40
:
-