Cisco Catalyst 4500 Series Message Manual page 26

Cisco ios system message guide
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

CHASSIS Messages
Error Message C4K_CHASSIS-3-INSUFFICIENTPOWER:Insufficient power to bring up module
in slot [dec]
Explanation
the module up. The switch holds the module in reset mode to consume less power.
Recommended Action
Error Message C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:
Insufficient power supplies present for specified configuration
Explanation
supplies than required for the existing configuration.
Recommended Action
Error Message C4K_CHASSIS-3-INVALIDMGMTETHERNETADDR: Chassis SPROM not set or
invalid MAC address range
Explanation
range. The contents of the system's SPROM are bad, so the out of band management port does not
have a MAC address.
Recommended Action
switch components for repair or replacement.
Error Message C4K_CHASSIS-3-LINECARDMUXBUFFERTOSUPALIGNMENTWRONG:Linecard [dec]
MuxBuffers aligned towards supervisor in slot [dec] instead of [dec]
Explanation
configured to work with the standby supervisor engine. The switching module is completely
unusable in this condition.
Recommended Action
work, try resetting the switch. If the problem persists, contact your technical support representative.
Error Message C4K_CHASSIS-3-MIXINVOLTAGEDETECTED:Power supplies in the chassis are
receiving different voltage inputs
Explanation
supported.
Recommended Action
the same type.
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
2-6
The module type was identified, but the switch does not have sufficient power to bring
Add or replace a power supply to expand the power capacity of the chassis.
The system software detected that the current chassis configuration has fewer power
Add a power supply to meet the needs of the current chassis configuration.
The out of band management port uses a MAC address from the system's MAC address
Contact your technical support representative. You may need to return some
The mux buffers that work with the switching module in the mentioned slot are
Try removing and reinserting the affected switching module. If that doesn't
All the inputs to a chassis must be at the same voltage. Mixed voltage inputs are not
Change the power supplied to the switch so that all inputs to the chassis are of
Chapter 2
Messages and Recovery Procedures
OL-11541-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents