Cisco Catalyst 4500 Series Message Manual page 120

Cisco ios system message guide
Hide thumbs Also See for Catalyst 4500 Series:
Table of Contents

Advertisement

SUPERVISOR Messages
Error Message C4K_SUPERVISOR-3-FANTRAYSEEPROMREADFAILED: Failed to read fan tray's
seeprom
Explanation
should occur only in a prototype switch used in an early field trial.
Recommended Action
representative. You may need to return some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERLOOPBACKFAILED: Failed to put [char]
supervisor's module [dec] muxbuffers in loopback
Explanation
This might indicate problems with the line card mux buffers in the Catalyst 4500 series chassis.
Recommended Action
technical support representative. You may need to return some switch components for repair or
replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERREADLOOPBACKFAILED: Failed to read whether
[char] supervisor's module [dec] muxbuffers are in loopback
Explanation
This might indicate problems with the line card mux buffers in the Catalyst 4500 series chassis.
Recommended Action
technical support representative. You may need to return some switch components for repair or
replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERSEEPROMREADFAILED: Failed to read mux buffer
[dec]'s serial eeprom
Explanation
Recommended Action
technical support representative. You may need to return some switch components for repair or
replacement.
Error Message C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMINVALID: Invalid Netflow Services
Card seeprom data
Explanation
programmed.
Recommended Action
prompt.
Catalyst 4500 Series Switch Cisco IOS System Message Guide Release 12.2(31)SGA
2-100
A failure occurred while reading the system fan tray serial EEPROM. This message
Check the chassis serial EEPROM information. Contact your technical support
The serial-to-wire write operation to put the line card mux buffers in loopback failed.
Power cycle the switch. If the serial EEPROM is still invalid, contact your
The serial-to-wire write operation to put the line card mux buffers in loopback failed.
Power cycle the switch. If the serial EEPROM is still invalid, contact your
A failure occurred while reading the mux buffer serial EEPROM.
Power cycle the switch. If the serial EEPROM is still invalid, contact your
The serial EEPROM on the NetFlow Services Card cannot be read or was not
For more information, enter the sprom read nffc command at the ROMMON
Chapter 2