Download Print this page

Cisco Prisma II Installation And Operation Manual page 83

Reverse video receiver and reverse data receiver
Hide thumbs Also See for Prisma II:

Advertisement

Checking Reverse Receiver Alarms
Introduction
Using LCI, you can check the alarm status of various parameters. Alarms that you
can check are listed below.
Alarm
Function
Rx 1 Optical
Optical
Input Power
input 1
Rx 2 Optical
Optical
Input Power
input 2
Module
Module
Temperature
Temp
Alarms limits fall into one of the following categories.
• Major low
• Minor low
• Minor high
• Major high
78-713378-01 Rev C
Major
Minor
Minor
Low
Low
High
Limit
Limit
Limit
-20
-4
2
-20
-4
2
-125
-85
85
Operation Using LCI
Major
High
Limit
Hysteresis
3.2
1
3.2
1
125
1
Operating
Range
-17.0 to +2.0 dBm
-17.0 to +2 dBm
-40°C and 65°C