Configuring the Reverse Receiver Using the ICIM
Configurable Parameters
Configurable parameters for the Prisma II Reverse Receiver are listed below.
Control
Function
Mute1,
Force Mute. Muting of the RF signal and
removal of power to the amplifier only if the
Mute2
Enable control is on for this particular side.
Enable1,
Enables or disables unit operation, i.e.,
muting enabled and no alarm capability
Enable2
Alarm1,
Force Alarm. Alarm relay is manually
overridden only if the Enable control is On.
Alarm2
This sets a particular side to alarm as if there
was an internal alarm, i.e., Alarm output
high, muting on as per Force Mute above
Master1,
Configures the module as master or slave. If
set to Master, the unit is controlled only by
Master2
the Enable control above. If set to Slave, the
unit is controlled by a combination of the
Enable control and the external input
CNT_IN_1 or CNT_IN_2.
Atten1
Sets the attenuation level of the output RF
signal.
Atten2
NomPwr1,
The nominal input optical power level, in
NomPwr2
dBm.
3-16
Operation Using the ICIM
Values
Default
ON or OFF
OFF
ON or OFF
ON
ON or OFF
OFF
ON or OFF
ON
Decimal number
0 dB
between 0 and 20
dB, increments of
0.5 dB
Decimal number
0 dB
between –20 and
0 dBm,
increments of 0.5
dBm