Configuring the Reverse Receiver
Introduction
Using LCI, you can configure the parameters listed below.
Configurable Parameters
Configurable parameters for the Prisma II Reverse Receiver are listed below.
Control
Function
Rx 1 Mute
Force Mute. Muting of the RF signal and
Switch,
removal of power to the amplifier only if the
Enable control is on for this particular side.
Rx 2 Mute
Switch
Rx 1 Receiver
Enables or disables unit operation, i.e.,
Enable,
muting enabled and no alarm capability.
Rx2 Receiver
Enable
Rx 1 Manual
Force Alarm. Alarm relay is manually
Alarm
overridden only if the Enable control is On.
This sets a particular side to alarm as if there
Rx 2 Manual
was an internal alarm, i.e., Alarm output
Alarm
high, muting on as per Force Mute above
Rx 1 Master
Configures the module as master or slave. If
Select
set to Master, the unit is controlled only by
the Enable control above. If set to Slave, the
Rx 2 Master
unit is controlled by a combination of the
Select
Enable control and the external input
CNT_IN_1 or CNT_IN_2.
Rx 1
Sets the attenuation level of the output RF
Attenuator
signal.
Rx 2
Attenuator
4-22
Operation Using LCI
Values
Default
On = Mute On
Off
Off = Mute Off
On = Enabled
On
Off = Disabled
On = Alarm On
Off
Off = Alarm Off
On = Master On
On
Off = Slave On
Decimal number
0
between 0 and 20
dB, increments of
0.5 dB
78-713378-01 Rev C