Honeywell MultiRAE Series User Manual page 185

Portable multi-gas monitor
Table of Contents

Advertisement

Communication
and
Data Download
Wireless Network
Wireless
Frequency
Wireless Range
EM
No effect when exposed to 0.43mW/cm
Immunity
at 12")
-4° to 122° F (-20° to 50° C)
Operating
Temperature
Benzene-specific measurement operating range: 32° to 122° F (0° to 50° C)
Humidity
0% to 95% relative humidity (non-condensing)
Dust and
Water
IP-65 (pumped), IP-67 (diffusion)
Resistance
E, F, G; T85°C
SIRA 11ATEX2152X,
(for PGM62x0/PGM62x6)
SIRA 11ATEX2152X,  
(for PGM62x8)
UM=20V
Hazardous
Location
IECEx SIR 11.0069X, Ex ia IIC T4 Ga, Ex ia I Ma  (for PGM62x0/PGM62x6)
Approvals
IECEx SIR 11.0069X, Ex ia d IIC T4 Gb, Ex ia I Ma  (for PGM62x8)
IECEx TSA 13.0021X / ANZEx 13.3023X
Ex ia IIC T4 Ga
Ex ia I Ma
(PGM62x0/PGM62x6)
Ex ia d IIC T4 Gb
Ex ia I Ma
(PGM62x8)
CE
EMC directive: 2014/30/EU
Honeywell MultiRAE Series™
• User-configurable datalogging interval (from 1 to 3,600 seconds)
• Download data and upload instrument setup from PC through charging
cradle or
by using BLE module and dedicated App
• Wireless data and alarm status transmission via built-in RF modem
(optional)
Mesh RAE Systems Dedicated Wireless Network (or BLE or Wi-Fi network
for Wi-Fi-equipped instruments)
ISM license-free band, 868 MHz or 900 MHz FCC Part 15, CE R&TTE,
IEEE 802.11 b/g bands (2.4 GHz)
Up to 650 ft (200 m) for sub 1GHz Mesh Radio (receiving data >80%),
up to 330 ft (100 m) for Wi-Fi (receiving data >80%),
up to 15 ft (5 m) for BLE 
Exia Class I, Division 1, Groups A, B, C, D, T4; Class II, Division 1, Groups
2
RF interference (5-watt transmitter
2460
II  1G Ex ia IIC T4 Ga,
2460
II  2G Ex ia d IIC T4 Gb,
180
I M1 Ex ia I Ma
I M1 Ex ia I Ma