Honeywell MultiRAE Series User Manual page 115

Portable multi-gas monitor
Table of Contents

Advertisement

automatically assigns a new Site ID to each measurement you take. The pump turns on and the
instrument begins collecting data. To stop sampling, press [N/-] while the main display is
showing. You will see a new screen that says, "Stop sampling?" Press [Y/+] to stop sampling.
Press [N/-] if you want sampling to continue. Refer to section 8.2 for more information on
operation in Search Mode.
Pump Speed
If the MultiRAE is equipped with a pump, the pump can operate at two speeds, high and low.
Running at low speed is quieter, extends pump lifespan, and conserves a small amount of
power. There is almost no difference in sampling accuracy.
Zero At Start
If your MultiRAE has been configured to perform a zero (fresh air) calibration upon startup,
called Zero At Start, then the startup routine is interrupted so that you can perform a fresh air
calibration for all sensors prior to using the instrument.
If you do not want to perform a zero calibration, press [MODE] to bypass it. If you start a zero
calibration and want to abort it, press [N/-], and the calibration stops and the main display is
shown.
Fast Startup
Fast Startup reduces the amount of time between when the instrument is turned on and is
ready for use. It skips showing you many settings and is best suited to environments where the
MultiRAE is turned on and off very often during a given day. If Fast Startup is not selected, then
when the instrument starts, it shows you details of each sensor, including calibration
information, high and low alarm settings, etc.
Benzene Mode (MultiRAE Or MultiRAE Pro Equipped for Benzene Sampling Only)
When equipped with a 9.8eV lamp and set for benzene sampling, a MultiRAE or MultiRAE Pro
does not offer Search Mode. It operates in TVOC Mode (equivalent to Hygiene Mode) or
Benzene Mode.
Temperature Units
The display unit of the internal temperature sensor can be switched between Fahrenheit and
Celsius.
Language
English is the default language, but other languages can also be selected for the instrument.
Note: The language can only be changed through Safety Suite Device Configurator (SSDC).
Site ID
Choose and enter an 8-digit Site ID to uniquely identify the particular site where the instrument
is to be used. The first four digits can be an alphabet letter or number, while the last four digits