Appendix B. DR File Type Explanations
B.5.1 Boiler File Flexibility
Free choice of first tube to be tested
Free choice of distance with "skipping" of tubes
Note: If you are measuring ribbed tubes and recording in a Boiler file, you can automatically insert "OBST" into a designated series of C
(center) positions. Set up the file with the "Points on Tube" option set to "L, C, R" (left, center, right). At a specific center (c) data
location, press F3 (OBST). A screen appears similar to Figure x below.Enter the end tube number for the last center location to
contain OBST. The DMS Go then inserts OBST into the designated center locations The user may then attach a "RIBBED" comment
to all obstructed positions
.
144
Your Complete Source for
Testing Equipment. Since 1969!
Figure 36: OBST Setup Option