GE Druck DPI 705 User Manual

GE Druck DPI 705 User Manual

Digital pressure indicator
Hide thumbs Also See for Druck DPI 705:

Advertisement

GE
Sensing & Inspection Technologies
Druck DPI 705/DPI 705 IS Series
Digital Pressure Indicator
User Manual K0214
English
1 - 6
Français
Deutsch
13 - 18
Italiano
Español
Português
g
7 - 12
19 - 24
25 - 30
31 - 36

Advertisement

Table of Contents
loading

Summary of Contents for GE Druck DPI 705

  • Page 1 Sensing & Inspection Technologies Druck DPI 705/DPI 705 IS Series Digital Pressure Indicator User Manual K0214 English 1 - 6 Français 7 - 12 Deutsch 13 - 18 Italiano 19 - 24 Español 25 - 30 Português 31 - 36...
  • Page 2 ©The General Electric Company. All rights reserved...
  • Page 3 Approved Service Agents For the list of service centres visit our web site: www.gesensinginspection.com Symbols This equipment meets the requirements of all relevant European safety directives. The equipment carries the CE mark. This symbol, on the instrument, indicates that the user should refer to the user manual.
  • Page 4 Autorisierte Servicevertretungen Eine Liste der Servicezentren finden Sie auf unserer Webseite: www.gesensinginspection.com Symbole Dieses Gerät erfüllt die Anforderungen der entsprechenden europäischen Sicherheitsrichtlinien. Das Gerät ist mit dem CE- Prüfzeichen versehen. Bei diesem Symbol auf dem Gerät sollte der Anwender im Handbuch nachschlagen.
  • Page 5 Agentes de servicio técnico autorizados Si desea consultar la lista de centros de servicio técnico, visite nuestro sitio web: www.gesensinginspection.com Símbolos Este equipo cumple los requisitos de todas las directivas europeas de seguridad pertinentes. El equipo posee la marca CE. Este símbolo, en el instrumento, indica que el usuario debe consultar el manual del usuario.
  • Page 6 intentionally left blank K0214 Issue No. 5...
  • Page 7 DPI 705 Series Digital Pressure Indicator Introduction The Druck DPI 705 pressure indicator uses a micro-machined silicon transducer to produce a pressure reading in units of pressure measurement. These user instructions include the operations for all DPI 705 Pressure Indicators, safety instructions and the requirements for intrinsically safe instruments.
  • Page 8 Display Symbols Filter applied Batteries are low, replace (10 reading rolling average) observing polarity shown on case TARE Tare applied Displayed reading - maximum value Alarm - pressure value more than alarm setting Displayed reading - minimum value (flashing) Leak test in progress Displayed reading - leakage (per (count down) minute)
  • Page 9 Intrinsically Safe Pressure Indicators Introduction These instructions detail the requirements for using the DPI 705 Intrinsically Safe Pressure Indicator in a hazardous area. Read the whole publication before starting. Special note This instrument has been certified by ATEX and CSA. The batteries certfiied for use by each certifying body are different.
  • Page 10 CSA Certification Markings: Ex ia IIC T4, Class 1, Zone 0 and Class 1, Div.1 Groups A, B, C & D ............. hazardous location designation 1999 LR110032-3 ............certificate reference Amb Temp -10°C to +50°C ........ambient temperature range ........CSA monogram DPI 705 IS ..............
  • Page 11 Calibration Instructions WARNING: CALIBRATE DPI 705 IS INSTRUMENTS IN A SAFE AREA. The instrument performs a two-point compensation at ZErO and FS (full-scale.) Preparation Connect the instrument to a pressure source that has an accuracy three times better than the instrument.
  • Page 12 K0214 Issue No. 5...