Appendix D
Chassis and Module LEDs
S e n d d o c u m e n t c o m m e n t s t o n e x u s 7 k - d o c f e e d b a c k @ c i s c o . c o m
Table D-4
Table D-4
LED
Status Green
ID
Table D-5
DC power supply units have Input 1, Input 2, Input 3, and Input 4 LEDs. The Output, Fault, and ID LEDs
have the same function for both the AC and DC power supply units.
Table D-5
LED
Input 1
Input 2
Input 3
Input 4
Output
OL-23069-06
describes the fabric module LEDs.
Fabric Module LEDs
Status
Description
All diagnostics pass. The module is operational (normal initialization sequence).
Red
The diagnostic test has failed. The module is not operational because a fault has
occurred during the initialization sequence.
or
he inlet air temperature of the system has exceeded the safe operating
T
temperature limits of the card (a major environmental warning). The card has
been shut down to prevent permanent damage.
Blinking
The fabric module has just been inserted and is booting up.
red
or
An overtemperature condition has occurred and the module has powered down.
or
The power was turned off with a CLI command.
or
The module is resetting and both ejector levers are out.
Blinking
The operator has activated this LED to identify this module in the chassis.
blue
Off
This module is not being identified.
describes the power supply unit LEDs. AC power supply units have Input 1 and Input 2 LEDs.
Power Supply LEDs
Color
Condition
Green
The AC or DC input voltage is within the valid range.
Off
The AC or DC input voltage is outside the valid range.
Green
The AC or DC input voltage is within the valid range.
Off
The AC or DC input voltage is outside the valid range.
Green
The DC input voltage is within the valid range.
Off
The DC input voltage is outside the valid range.
Green
The DC input voltage is within the valid range.
Off
The DC input voltage is outside the valid range.
Green
The AC or DC output power is within the valid range.
Off
The AC or DC output power is outside the valid range.