See Appendix B for editing names.

Changing Module Options

Each module has a unique set of options that specifically applies to the functionality of the module being edited.
8.
Use the left and right arrow keys to move between available options.
9.
Option settings are edited by pressing the up or down arrow.
9.2.2 Adding a Module
If you need to add a new hardware module to the system, follow these steps.
You must be in the Main Menu to perform this task. If necessary, enter the Installer Code.
1.
Enter the installer code.
2.
Press 7 for Program Menu.
3.
Press 1 to enter module menu.
4.
Press 2 to add a module.
5.
From the next screen, use the up or down arrow to choose a module type to add from the <New Module Type> screen.
The screen will display "Adding module [#]..." for a few moments. You will be returned to the <New Module Type> screen
where you can add additional modules if desired.
You must save changes when you exit the Program Menu or the new module will not be added.
NOTE: If you Add a Module that has not been physically connected, the panel will go into trouble after it reinitializes (when you exit the
Program Menu). When the new module is attached, the trouble will correct itself automatically.
9.2.3 Deleting a Module
If you ever need to delete a module, follow these steps.
You must be in the Main Menu to perform this task. If necessary, enter the Installer Code.
1.
Enter the installer code.
2.
Press 7 for Program Menu.
3.
Press 1 to enter module menu.
4.
Press 3 to delete a module.
5.
From the next screen, select a module to delete.
6.
A warning screen will display. If you want to proceed with deleting the module, select Yes. To cancel, select No.
9.2.4 View Module List
1.
Enter the installer code.
2.
Press 7 for Program Menu.
3.
Press 1 to enter module menu.
4.
Press 4 to view module list.

9.3 Zone

Through the zone option in the program menu you can edit and view zone points. Selections made here affect all detectors and switches
in the zone. Up to 250 zones can be used in the system.
9.3.1 Edit Zone
Features that can be edited through the edit zone option are zone name, zone properties (which includes, zone type, and detector sensitiv-
ity), and zone accessory options.