Honeywell 6808 Installation And Operation Manual page 129

Addressable fire alarm control panel
Table of Contents

Advertisement

Event Description
F3 Mapping Inhibited Restoral
F4 Mapping Inhibited
F4 Mapping Inhibited Restoral
Fire Reset
Fire System Overridden
Fire System Override Restore
Ground fault condition trouble
Ground fault condition trouble
restore
Initial power up
Local programming aborted or end-
ed with errors
Local programming begin
Local programming ended
normally
Network node trouble (panel miss-
ing)
Network node trouble restore
(panel no longer missing)
OPG Inhibit Trouble
OPG Inhibit Trouble Restore
OPG Inhibit of Releasing Group
OPG Inhibit of Releasing Group Re-
store
Phone line 1 trouble detected
Phone line 1 trouble restore
Phone line 2 trouble detected
Phone line 2 trouble restore
Printer is off-line trouble
Printer is off-line trouble restore
Printer is out of paper trouble
Printer is out of paper trouble restore
Releasing Notif/Control Circuit
Disabled
Releasing Notif/Control Circuit en-
abled
Remote programming aborted or
ended with errors
Remote programming ended nor-
mally
Repeater ground fault trouble
Repeater ground fault trouble re-
store
Repeater missing trouble
Repeater missing trouble restore
6808 Manual — P/N LS10146-001SK-E:C 09/28/2017
SIA Reporting Format
SIA pi Modifier
Module
SIA
Parameter Fixed Length
ID # (If
Event
Any)
Codes
FJ
2003
FT
2004
FJ
2004
OR
0
FS
0
FR
0
YP
Exp. ID
YQ
Exp. ID
RR
0
LU
0
LB
0
LS
0
EM
Panel ID
EN
Panel ID
FT
Group # +
1000
FJ
Group # +
1000
SS
Group # +
1000
SR
Group # +
1000
LT
1
LR
1
LT
2
LR
2
VZ
Exp. ID
VY
Exp. ID
VO
Exp. ID
VI
Exp. ID
pi Exp. ID SS
Point #
pi Exp. ID SR
Point #
RU
0
RS
0
EM
0103
EN
0103
EM
0100
EN
0100
Table 11.3 : Reporting Formats Table
Contact ID Reporting Format
SIA
Qualifier
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
FJNN002003
3
FTNN002004
1
FJNN002004
3
ORNN000000
1
FSNN000000
1
FRNN000000
3
YPNNXX0000
1
YQNNXX0000
3
RRNN000000
1
LUNN000000
1
LBNN000000
1
LSNN000000
1
EMNNNN0000
1
ENNNNN0000
3
FTNN001GGG
1
FJNN001GGG
3
SSNN001GGG
1
SRNN001GGG
3
LTNN000001
1
LRNN000001
3
LTNN000002
1
LRNN000002
3
VZNNXX0000
1
VYNNXX0000
3
VONNXX0000
1
VINNXX0000
3
SSNNXXPPPP
1
SRNNXXPPPP
3
RUNN000000
1
RSNN000000
1
EMNN000103
1
ENNN000103
3
EMNN000100
1
ENNN000100
3
Reporting
Event
Group #
Contact #
Code
570
00
003
570
00
004
570
00
004
401
00
000
245
00
000
245
00
000
310
Exp. ID
000
310
Exp. ID
000
305
00
000
628
00
000
627
00
000
628
00
000
334
Panel ID
000
334
Panel ID
000
320
00
Group #
320
00
Group #
203
00
Group #
203
00
Group #
351
00
000
351
00
000
352
00
000
352
00
000
336
Exp. ID
000
336
Exp. ID
000
335
Exp. ID
000
335
Exp. ID
000
203
Exp. ID
Point #
203
Exp. ID
Point #
413
00
000
412
00
000
334
Panel ID
103
334
Panel ID
103
334
Panel ID
100
334
Panel ID
100
129

Advertisement

Table of Contents
loading

Table of Contents