List Of Sk Slc Devices - Honeywell 6808 Installation And Operation Manual

Addressable fire alarm control panel
Table of Contents

Advertisement

Section 7: SK, SD and SWIFT
CAUTION: TO AVOID THE RISK OF ELECTRICAL SHOCK AND DAMAGE TO THE UNIT, POWER SHOULD BE OFF AT
!
THE CONTROL PANEL WHILE INSTALLING OR SERVICING.

7.1 List of SK SLC Devices

The following SK SLC devices can be used with the control panel. See the appropriate section number in this manual or the device
installation instructions (packaged with the device) for more information..
NOTE: The control panel supports the use of either SK or SD SLC devices. You cannot install both SLC device types on the control panel.
Model Number
SK-PHOTO
SK-PHOTO-T
SK-ACCLIMATE
SK-BEAM
SK-BEAM-T
SK-DUCT
SK-HEAT
SK-HEAT-ROR
SK-HEAT-HT
SK-PULL-SA
SK-PULL-DA
SK-ISO
SK-MONITOR
SK-MINIMON
SK-MONITOR-2
SK-MON-10
SK-RELAY
SK-RELAYMON-2
SK-RELAY-6
SK-ZONE
SK-ZONE-6
SK-CONTROL
SK-CONTROL-6
SK-FIRE-CO
B210LP
B224BI-WH / IV
B224RB-WH / IV
B200SR-WH / IV
B200S-WH / IV
B501
B501-WHITE / IV / BL
B200SR-LF-WH/ IV
B200S-LF-WH / IV
SK-PHOTO-W
SK-PHOTO-R-W
SK-PHOTO-T-W
SK-HEAT-W
SK-HEAT-ROR-W
SK-HEAT-HT-W
74
SK
Photoelectric smoke detector
Photoelectric smoke detector with thermal (135°F)
Multi criteria photoelectric smoke detector with thermal (135°F)
Reflected beam smoke detector without test feature
Reflected beam smoke detector with test feature
Photoelectric duct smoke detector with extended air speed range
Fixed temperature thermal detector (135°F)
Rate-of-rise thermal detector with 135° fixed temperature
Fixed high temperature thermal detector (190°F)
Addressable single action pull station
Addressable dual action pull station
Fault isolator module
Monitor module
Mini monitor module
Dual input monitor module
10 input monitor module
Addressable relay module
Dual relay/monitor module
Six relay control module
Addressable zone interface module
Six zone interface module
Supervised control module
Six circuit supervised control module
CO Smoke Detector
6" mounting base
6" isolator base. White or Ivory
6" relay base. white or Ivory
6" temporal sounder base. White or Ivory
Intelligent Sounder Base. White or Ivory
4" mounting base
4" mounting base
Low Frequency Sounder Base. white
Low Frequency Sounder Base. White
Photoelectric smoke detector. White
Photoelectric replacement smoke detector with remote test capability
in DNR. White
Photoelectric smoke detector with thermal (135°F) White
Fixed temperature thermal detector (135°F). White
Rate-of-rise thermal detector with 135° fixed temperature. White
Fixed high temperature thermal detector (190°F). White
Wireless SLC Device Installation
Model Name/Description
Table 7.1 SK SLC Devices
6808 Manual — P/N LS10146-001SK-E:C 09/28/2017
Section/ Install
Sheet PN
I56-3426-00
I56-3433-00
I56-3432-000
I56-3429-000
I56-3446-001
I56-3447-001
I56-3445-000
I56-3442-000
I56-3444-000
I56-3435-000
I56-3443-000
I56-3438-000
I56-3735-000
I56-3439-000
I56-3440-000
I56-3441-000
I56-3436-000
I56-3437-000
I56-3945-000
I56-0595-00
I56-0725-00
I56-3737-00
I56-3392-00
I56-3387-00
I56-0357-00
I56-6527-00
I56-4152-00
I56-4151-00
I56-6527-00
I56-6528-00
I56-6530-00
I56-6529-00
I56-6529-00
I56-6529-00

Advertisement

Table of Contents
loading

Table of Contents