Event Description
Water flow switch trouble
Water flow switch trouble restore
Zone-based AUX1 switch alarm
Zone-based AUX1 switch alarm re-
store
Zone-based AUX1 switch disabled
Zone-based AUX1 switch enabled
Zone-based AUX1 switch trouble
Zone-based AUX1 switch trouble re-
store
Zone-based AUX2 switch alarm
Zone-based AUX2 switch alarm re-
store
Zone-based AUX2 switch disabled
Zone-based AUX2 switch enabled
Zone-based AUX2 switch trouble
Zone-based AUX2 switch trouble re-
store
System-based Wireless Gateway
Trouble
System-based Wireless Gateway
Trouble - restore
Wireless Gateway Trouble
Wireless Gateway Trouble restore

11.2 SIA / Panels PI Modifier Reporting:

Events are sent to the central station as a variable length string:
The event format is:
EEZZZZ
Where:
EE
Event code (2 characters)
ZZZZ Event parameter (up to four digits – not zero filled)
1.
The account number is sent using an account block that is separate from the event block
2.
Multiple events can be sent within a single event block. Events are separated by a "/" character.
3.
Event parameter can be either a zone, point or module number.
4.
When reporting by point is enabled, the communicator uses a "pi" event to supersedes the actual point event to report the module
the point is linked to.
5.
Panel ID is not sent in the SIA event parameters.
For Example see Table 11.4:
Fire Alarm-Zone
Fire Alarm-Zone
6808 Manual — P/N LS10146-001SK-E:C 09/28/2017
SIA Reporting Format
SIA pi Modifier
Module
SIA
ID # (If
Event
Any)
Codes
pi Exp. ID ST
pi Exp. ID SJ
pi Exp. ID UA
pi Exp. ID UH
pi Exp. ID UB
pi Exp. ID UU
pi Exp. ID UT
pi Exp. ID UJ
pi Exp. ID UA
pi Exp. ID UH
pi Exp. ID UB
pi Exp. ID UU
pi Exp. ID UT
pi Exp. ID UJ
pi Exp. ID UT
pi Exp. ID UJ
pi Exp. ID UT
pi Exp. ID UJ
Table 11.3 : Reporting Formats Table
Event
Zone
n/a
Zone
n/a
Table 11.4: SIA- Panels - PI Modifier Reporting Examples
SIA
Parameter Fixed Length
Format NN -
panel ID
XX- SBUS ID
ZZZ- Zone #
PPPP- Point #
GGG- Group #
E- Emergency #
RRRR-Receiver #
Point #
STNNXXPPPP
Point #
SJNNXXPPPP
Point #
UANNXXPPPP
Point #
UHNNXXPPPP
Point #
UBNNXXPPPP
Point #
UUNNXXPPPP
Point #
UTNNXXPPPP
Point #
UJNNXXPPPP
Point #
UANNXXPPPP
Point #
UHNNXXPPPP
Point #
UBNNXXPPPP
Point #
UUNNXXPPPP
Point #
UTNNXXPPPP
Point #
UJNNXXPPPP
Point #
UTNNXXPPPP
Point #
UJNNXXPPPP
Point #
UTNNXXPPPP
Point #
UJNNXXPPPP
n/a97
15
n/a
n/a
05
n/a
Contact ID Reporting Format
Qualifier
Event
Group #
Code
1
373
Exp. ID
3
373
Exp. ID
1
140
Exp. ID
3
140
Exp. ID
1
571
Exp. ID
3
571
Exp. ID
1
373
Exp. ID
3
373
Exp. ID
1
140
Exp. ID
3
140
Exp. ID
1
571
Exp. ID
3
571
Exp. ID
1
373
Exp. ID
3
373
Exp. ID
1
373
Exp. ID
3
373
Exp. ID
1
373
Exp. ID
3
373
Exp. ID
EE-ZZ
FA15
EE-Z
FA5
Reporting
Contact #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
Point #
137