The UPS allows the Thor VM1 to continue operation when not mounted in a dock or
when the vehicle battery is being swapped. When fully charged the UPS battery is
designed to power the Thor VM1 for a minimum of 30 minutes at temperatures of -20ºC
(-4ºF) or greater. For the extended temperature version of the Thor VM1, the UPS pro-
vides a minimum of 10 minutes of operation between -20ºC (-4ºF) and -30ºC (-22ºF).
If operating on UPS power and the UPS battery becomes critically low, the Thor VM1
performs a controlled shutdown.
If there is no external power available, there must be 10% or greater power in the UPS
battery or the Thor VM1 does not power on.
The UPS status LED and the Battery Control Panel can be used to monitor the state of
the UPS battery.
Safety requirements restrict the temperature at which the Li-Ion UPS bat-
tery can be charged. Charging is disabled if the temperature is outside of
the 0ºC to 35ºC safe charging range. In order to maintain UPS charge the
Thor VM1 should have power applied while the unit is within the safe
charging range for at least an hour each day.
Safe Charging Temperature Range
The internal temperature of the Thor VM1 is the trigger for UPS battery charging.
When the Thor VM1 is operated in an environment where the UPS battery is not able to
charge due to temperature extremes, the Thor VM1 should be removed to a location
within the safe charging temperature range during off hours. A discharged UPS battery
cannot protect against data loss in the event vehicle power is interrupted.
Charging Timeout
26
The UPS battery is not charged when the internal Thor VM1 temperature is below 0°C
(32°F). This corresponds to an ambient (room) temperature of approximately -10°C
(-14°F).
The UPS battery is not charged when the internal Thor VM1 temperature is above
45°C (113°F). This corresponds to an ambient (room) temperature of approximately
35°C (95°F).
If the UPS battery cannot be charged due to a temperature extreme, the
LED
is amber. Move the Thor VM1 to a different location to charge the UPS battery.
A fully discharged UPS battery normally recharges in less than 4 hours when the Thor
VM1 is in a powered dock and within the safe charging temperature range.
If the UPS battery is not charged before an 8 hour (or 4 hours for some earlier
software revisions) timeout period expires, the
The charge timeout is reset if charging resumes upon application of external power.
The charge timeout is reset if charging resumes when the Thor VM1 enters the
permissible temperature range for charging.
If the charge timeout occurs, remove the Thor VM1 from the dock and
UPS
Battery. Reinstall the Thor VM1 in the dock and power on.
Thor VM1 with Microsoft Windows Embedded Standard 2009 User Guide
UPS Status LED
is amber.
UPS Status
Disconnect