Module Parameters; Basic Setting - Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

14.2

Module Parameters

Set the module parameter. The module parameter has the basic setting, application setting, interrupt setting, and refresh
setting.
Select the module parameter from the tree on the following window.
[Navigation]  [Parameter]  [Module Information]  [Target module]  [Module Parameter]

Basic setting

Set the parameter required to use the positioning module.
Item
■Basic parameter 1
Unit setting
Electronic gear selection
No. of pulses per rotation (16 bits)
Movement amount per rotation (16 bits)
No. of pulses per rotation (32 bits)
Movement amount per rotation (32 bits)
Unit magnification
Pulse output mode
14 PARAMETER SETTING
312
14.2 Module Parameters
Setting range
• 0: mm
• 1: inch
• 2: degree
• 3: pulse (default value)
• 0: 16bit (default value)
• 1: 32bit
1 to 65535 pulses (default value: 20000)
Refer to the right item. (default value: 20000)
1 to 200000000 pulses (default value: 20000)
Refer to the right item. (default value: 20000)
• 1: ×1 (default value)
• 10: ×10
• 100: ×100
• 1000: ×1000
• 0: PULSE/SIGN mode
• 1: CW/CCW mode (default value)
• 2: A-phase/B-phase multiple of 4
• 3: A-phase/B-phase multiple of 1
Reference
Page 372 [Pr.1] Unit setting
Page 379 [Pr.62] Electronic gear selection
Page 373 [Pr.2] No. of pulses per rotation (16 bits)
(Ap)
Page 374 [Pr.3] Movement amount per rotation (16
bits) (Al)
Page 379 [Pr.2] No. of pulses per rotation (32 bits)
(Ap)
Page 380 [Pr.3] Movement amount per rotation (32
bits) (Al)
Page 374 [Pr.4] Unit magnification
Page 375 [Pr.5] Pulse output mode

Advertisement

Table of Contents
loading