Setting examples of the condition data

The following shows setting examples of Condition data.
Example 1
This example uses the on/off state of a device as a condition.
• [Condition] If "[Md.141] BUSY: b0" (=Axis 1 BUSY signal) is "OFF"
[Da.15] Condition target
01H: Monitor data ([Md.31]
b12 to b15, [Md.140],
[Md.141])
Example 2
This example uses a numerical value stored in the buffer memory as a condition.
• [Condition] If the value stored in buffer memory addresses: 800 and 801 ("[Md.20] Current feed value" of Axis 1) is "100"
min.
[Da.15] Condition target
04H: Buffer memory (2 words)
Example 3
This example specifies an axis and the positioning data No. of the axis as the target for the simultaneous start.
• [Condition] The positioning data No.3 of the axis 2 is the target for the simultaneous start.
[Da.15] Condition target
05H: Positioning data No.
*1 Set 0000H for the starting axis (Axis that implemented the positioning start).
10 ADVANCED POSITIONING CONTROL
180
10.4 Setting the Condition Data
[Da.16] Condition
[Da.17] Address
operator
08H: SIG=OFF
[Da.16] Condition
[Da.17] Address
operator
04H: **≥P1
800
[Da.16] Condition
[Da.17] Address
operator
20H: Axis 2 specification
[Da.18] Parameter 1
[Da.19] Parameter 2
0CH: BUSY (Axis 1)
[Da.18] Parameter 1
[Da.19] Parameter 2
1000
[Da.18] Parameter 1
[Da.19] Parameter 2
*1
0003H in the upper 16 bits
*1