Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 317

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

Item
■OPR detailed parameter
OPR dwell time
Setting for the movement amount after
near-point dog ON
OPR acceleration time selection
OPR deceleration time selection
OP shift amount
OPR torque limit value
Deviation counter clear signal output time
Speed specification during OP shift
Dwell time during OPR retry
Setting of operation during uncompleted
OPR
*1
■Basic parameter 3
Extended parameter storage setting
*1 The basic parameter 3 setting is available only in GX Works3.
Setting range
0 to 65535 ms (default value: 0)
Refer to the right item. (default value: 0)
• 0: Acceleration time 0 (default value)
• 1: Acceleration time 1
• 2: Acceleration time 2
• 3: Acceleration time 3
• 0: Acceleration time 0 (default value)
• 1: Deceleration time 1
• 2: Deceleration time 2
• 3: Deceleration time 3
Refer to the right item. (default value: 0)
1 to 3000 (default value: 300)
1 to 65535 ms (default value: 11)
• 0: OPR speed (default value)
• 1: Creep speed
0 to 65535 ms (default value: 0)
• 0: Do not execute positioning control (default value)
• 1: Execute positioning control
• CPU (default value)
• Positioning module
Reference
Page 404 [Pr.49] OPR dwell time
Page 405 [Pr.50] Setting for the movement amount
after near-point dog ON
Page 406 [Pr.51] OPR acceleration time selection
Page 406 [Pr.52] OPR deceleration time selection
Page 407 [Pr.53] OP shift amount
Page 408 [Pr.54] OPR torque limit value
Page 408 [Pr.55] Deviation counter clear signal
output time
Page 408 [Pr.56] Speed specification during OP shift
Page 409 [Pr.57] Dwell time during OPR retry
Page 409 [Pr.58] Setting of operation during
uncompleted OPR
14 PARAMETER SETTING
14.2 Module Parameters
14
315

Advertisement

Table of Contents
loading