Mitsubishi Electric MELSEC iQ-F Series FX5 User Manual page 344

Positioning control - intelligent function module
Hide thumbs Also See for MELSEC iQ-F Series FX5:
Table of Contents

Advertisement

Monitor Data
The data indicates the control status. The data is stored in the buffer memory. Monitor the data as necessary.
The setting data is classified as follows.
Item
System monitor
Axis monitor data
Control Data
The data is used by users to control the positioning system.
The setting data is classified as follows.
Item
System control data
Axis control data
■Data setting timing
• The control using the control data is performed with programs.
• [Cd.41] Deceleration start flag valid is valid for only the value of when [Cd.190] PLC READY signal is turned off and on.
• Setting data is created for each axis.
• The initial values are determined for the parameters of Setting data, and are set as the factory default. (The
parameters related to axes that are not used are left at the initial values.)
• Setting data can be initialized with programs.
• Setting of Setting data with GX Works3 is recommended. The program for the setting is complicated and
many devices must be used. This will increase the scan time.
17 DATA USED FOR POSITIONING CONTROL
342
17.1 Types of Data
Description
Monitors the positioning module specifications and the operation history.
Monitors the data related to the operating axis, such as the current position
and speed.
Description
Backs up the setting data of the positioning module or initializes the backup
data.
Configures the settings related to the operation, controls the speed change
during operation, and stops or restarts the operation.