Setting the function using an external command signal
The skip function can also be executed using an external command signal.
The section shows a setting example and program example for skipping the control being executed in the axis 1 using an
external command signal.
■Setting data
Set the following data to execute the skip function using an external command signal.
Setting item
[Pr.42]
External command function
selection
[Cd.8]
External command valid
For details on the settings, refer to the following.
Page 399 [Pr.42] External command function selection
Page 458 [Cd.8] External command valid
■Program example
Add the following program to the control program, and write it to the CPU module.
Classification
Label Name
Module label
FX5PG_1.stnParameter_Axis_D[0].uExternalCommandFunctionSelection_D
FX5PG_1.stnAxisControlData_Axis_D[0].uExternalCommandValid_D
Global label, local
Define the global label or local label as follows. Setting Assign (Device/Label) for labels is not necessary because the unused internal
label
relay and data device are automatically assigned to the labels.
Setting
Setting detail
value
3
Set 3: Skip request.
1
Set 1: Validate external command.
Buffer memory address
Axis 1
Axis 2
62
212
1505
1605
Description
Axis 1 External command function
selection
Axis 1 External command valid
12 CONTROL SUB FUNCTION