[Pr.48] OPR retry
Set whether to perform OPR retry.
OPR retry
Do not perform OPR retry by limit switch
Perform OPR retry by limit switch
For the operation of OPR retry, refer to the following.
Page 211 OPR retry function
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.48] OPR retry
■Default value
The default value is 0: Do not perform OPR retry by limit switch for all the axes.

OPR detailed parameter

[Pr.49] OPR dwell time
When stopper method 1 is set in [Pr.43] OPR method set the time for the machine OPR to complete after the near-point dog
signal turns on in units of ms. Set a value equal to or grater than the movement time from the near-point dog signal ON to the
stop with the stopper. (If the OPR method is not Stopper method 1, the value in [Pr.49] OPR dwell time is irrelevant.)
■Buffer memory address
The following table shows the buffer memory address of this area.
Buffer memory name
[Pr.49] OPR dwell time
■Setting range
The setting range is 0 to 65535.
■Default value
The default value is 0 for all the axes.
17 DATA USED FOR POSITIONING CONTROL