Replacing Line Cards
Using SNMP Traps
The system supports SNMP traps that are triggered for conditions that may indicate the need to replace a line card. The
system provides the traps listed in the table below.
Table 84.
SNMP Traps for Line Cards
SNMP Trap
starCardVoltageFailure
starCardBootFailed
starCardFailed
starCardSWFailed
starCardRCCFailed
Description
A voltage regulation failure has been detected in a card.
A card has failed to start up properly. The card is not operational.
The card has failed and is no longer operational.
An unrecoverable software error has occurred on the card.
The RCC has failed.
Determining Whether a Line Card has Failed ▀
ASR 5000 Installation Guide ▄
251