Using The Ethernet Rj-45 Interfaces - Cisco ASR 5000 Series Installation Manual

Hide thumbs Also See for ASR 5000 Series:
Table of Contents

Advertisement

Cabling the Switch Processor Input/Output Line Card

Using the Ethernet RJ-45 Interfaces

The two RJ-45 interfaces are auto-sensing 10/100/1000Base-TX Ethernet interfaces. Refer to the figure and table that
follow for pinouts for the RJ-45 Ethernet ports.
Important:
with Radiated Emissions Criteria, you must use shielded-twisted pair (STP) copper cable and ensure that it is properly
terminated at both ends.
Important:
building or unexposed wiring or cabling only. These intra-building ports MUST NOT be metallically connected to
interfaces that connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as intra-building
interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from the exposed
OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces
metallically to OSP wiring.
Important:
This will assure proper reconnection should the card need to be serviced.
Figure 31.
Table 33.
SPIO Ethernet RJ-45 Interface Pinout
Pin
100Base-TX 100Mbps Cat5
1
TX+
2
TX-
3
RX+
4
No used
5
No used
6
RX-
7
No used
8
No used
RX = Receive Data TX = Transmit Data BI = BI directional data DA, DB, DC, DD = Data Pair A, B, C, and D
To comply with GR-1089 intra-building, lightning-immunity requirements and ensure compliance
The 1000Base-TX (RJ-45) management ports of the SPIO are suitable for connection to intra-
Be sure to label the interface cables with their destination prior to connecting them to the SPIO card.
SPIO Ethernet RJ-45 Interface
1000Base-TX 1Gbps Cat5+
BI DA+
BI DA-
BI DB+
BI DC+
BI DC-
BI DB-
BI DD+
BI DD-
Connecting to the Management LAN ▀
ASR 5000 Installation Guide ▄
111