▀ Chassis Slot Numbering and Assignments
Table 28.
Line Card Slot Assignments
Line Card Type
Switch Processor
Input/Output (SPIO)
Redundancy Crossbar Card
(RCC)
Ethernet 10/100 (FLC2)
Ethernet 1000 (GLC2)
Quad Gig-E (QGLC)
10 Gigabit Ethernet Card
(XGLC)
Optical (ATM) (OLC2)
Channelized (CLC2)
▄ ASR 5000 Installation Guide
94
Chassis Slot
Description
Number
24
Resides behind Primary SMC in slot 8.
25
Resides behind Redundant SMC in slot 9.
40
Resides behind Primary SMC in slot 8. It provides redundancy for all packet
processing application cards and for line cards installed in the upper-rear chassis,
slots 17 through 23 and 26 through 32.
41
Resides behind Redundant SMC in slot 9. It provides redundancy for all SMC
application cards and for line cards installed in the lower-rear chassis, slots 33
through 39 and 42 through 48.
17 through
Resides directly behind its corresponding packet processing card. Each packet
23, 26
processing card can support up to two FLC2s. The active card is installed in the
through 39,
upper rear chassis slot. The redundant card is installed in the lower rear chassis
or 42
slot.
through 48
17 through
Resides directly behind its corresponding packet processing card. Each packet
23, 26
processing card can support up to two GLC2s. The active card is installed in the
through 39,
upper rear chassis slot. The redundant card is installed in the lower rear chassis
or 42
slot.
through 48
17 through
Resides directly behind its corresponding packet processing card. Each packet
23, 26
processing card can support up to two QGLCs. The active card is installed in the
through 39,
upper rear chassis slot. The redundant card is installed in the lower rear chassis
or 42
slot.
through 48
17 through
Resides directly behind its corresponding packet processing card. The XGLC is a
23 and 26
full-height line card that occupies the upper and lower slots in the ASR 5000.
through 32
17 through
Resides directly behind its corresponding packet processing card. Each packet
23, 26
processing card can support up to two OLC2s. The active card is installed in the
through 39,
upper rear chassis slot. The redundant card is installed in the lower rear chassis
or 42
slot.
through 48
7 through
Resides directly behind its corresponding packet processing card. Each packet
23, 26
processing card can support up to two CLC2s. The active card is installed in the
through 39,
upper rear chassis slot. The redundant card is installed in the lower rear chassis
or 42
slot.
through 48
Line Card Installation