Uplink failover overview

Uplink failover is a fault tolerance function that changes communication paths in failure of the
LAN switch module or external network device. It is implemented by using together with SFT
(Switch Fault Tolerance), a teaming function of Intel® PROSet, or Linux bonding function on a
server blade.
The following figure shows the uplink failover operation.
External network device
Failure
LAN switch module #0
Set SFT mode of Intel® PROSet or Linux bonding function
Primary
[Setting outline]
1. Teaming setting to NIC on the server blade
(1) Set the SFT mode or Linux bonding function.
(2) Set the preferred primary (SFT), and Master (Linux binding function)
(The primary system is used as the communication routing.
2. Set uplink failover to the LAN switch module.
(1) Set uplink failover to the external port of the primary LAN switch module.
Switch communication paths
using SFT or Linux bonding function.
Server Blade
814
External network device
LAN switch module #1
Standby