Panasonic DVC PRO Studio AJ-D950P Service Manual page 53

Vtr/analog video interface kit
Table of Contents

Advertisement

necessary. (Refer to Cleaning Arm Unit Replacement and T1 Guide
Position Adjustment.)
5.7.2. Cleaning Arm Unit Replacement
(Removal of Cleaning Arm Unit)
1. Remove 2 screws (A) and remove the T1 Guide.
2. Hang off the tip portion (B) of Cleaning Arm Unit and hang off the
spring from Cleaning Arm Unit, then remove the Cleaning Arum
Unit as shown in the figure.
(Installation of Cleaning Arm Unit)
1. Install a Cleaning Arm Unit to the T2 Arm Unit. Then remove the
spring from the cleaner base plate and hook to cleaning arm unit.
Push the cleaning arm unit into T2 Arm Unit.
2. Push the Cleaner Solenoid. Rotate the cylinder and confirm that
the cleaner roller is rotated by the cylinder movement.
3. Install a T1 Guide.
4. After T1 Guide installation, T1 Guide position adjustment is
necessary.
5.7.3. T1 Guide Position Adjustment
1. Set the VTR in no tape loading mode.
< No tape loading procedures >
- Open the "Servo Adjust" menu in the "Service Menu".
- Select the item "T TORQUE" and press the search button to
53

Advertisement

Table of Contents
loading

Table of Contents