3-6-11
Tension Confirmation
Specification (PLAY)6.0+/-1gf
(REV) 9.0+/-2gf
PLAY¤ REV• ~ 1
Mode
Tape
Beginning of 63min.M Cassette
Tool
VFK1145(Tension Meter)
1.
Playback the beginning of 63min. M
cassette.
2.
Set a tension meter between S3 and S4
post.
3.
Confirm the tension is in the specification.
4.
Set the VTR is in REV mode.
5.
Set the tension meter between S4 and S5
posts.
6.
Confirm the tension is in the specification.
Do not damage a tape during measurement.