Setup menus
USER menu
<OPERATION>
No.
108
109
110
The underline on the setting item denotes the initial setting.
Memory stop function
z When the FF button is pressed, the VTR performs the regular fast forward operation since the zero point is not located in the
direction of operation.
x When the REW button is pressed, the PREROLL lamp lights (the SHTL lamp lights as well), the VTR proceeds with the
preroll operation, and it automatically stops when it reaches the position where the counter reads "0."
c When the REW button is pressed, the VTR performs the regular rewinding operation since the zero point is not located in the
direction of operation.
v When the FF button is pressed, the PREROLL lamp lights (the SHTL lamp lights as well), the VTR proceeds with the preroll
operaiton, and it automatically stops when it reaches the position where the counter reads "0."
(continued)
Item
Setting
Superimposed
Superimposed
No.
display
display
CAP.LOCK
0000
0001
AUTO REW
0000
0001
MEMORY
0000
STOP
0001
FWD direction
3
REW button
4
FF button
– 50 –
4F
This selects the CAPSTAN LOCK mode for the 4F and 8F
settings of the CF switch.
8F
0: 4F mode
1: 8F mode
<Note>
This setup menu is not displayed in the 525 mode.
This selects whether to rewind the tape automatically to the
OFF
tape start when the tape end is detected.
ON
0: The tape stops at the tape end.
1: The tape is rewound to the tape start.
OFF
This selects whether the VTR is to stop automatically when
the counter value reaches "0" during a fast forwarding or
ON
rewinding operation in the CTL mode.
0: The VTR does not stop.
1: The VTR stops automatically.
<Notes>
1. The stop mode concerned is either the stop or the still-
picture (SHTL STILL) mode depending on the setup menu
No. 315 (AFTER CUE-UP) setting.
2. When both the AUTO REW function and MEMORY function
have been selected at the same time, the AUTO REW
function takes precedence.
The MEMORY STOP function does not work if it is
activated within a range of 0 ±2 frames.
Zero
point
1
FF button
2
REW button
Description