6.7.15. COMPOSITE PB LEVEL ADJ.
BOARD
SPEC.
TEST POINT
ADJ.
INPUT
MODE
TAPE
M.EQ
1. Adjust VR505 so that the Pb level is 486mV±7mV.
6.7.16. COMPOSITE PR LEVEL ADJ.
BOARD
SPEC.
TEST POINT
ADJ.
INPUT
MODE
TAPE
M.EQ
F3 V IN
V 486mV±7mV
Component PB out
VR505
Composite Color Bar
(75%, Setup 7.5%)
ASSEMBLE
WFM
F3 V IN
V 486mV±7mV
Component PR out
VR511
Composite Color Bar
(75%, Setup 7.5%)
ASSEMBLE
WFM
142