5.6.31. LISTA Connection and Start
Test Point
M. EQ.
Tape
Tool
1. Connect the LISTA cable with the A/D board in the PC.
2. Connect the LISTA clips to the following Test Points.
A. ATF:TP732
B. HSW:TP722(RP HSW) or TP723(PB HSW)
C. GND:TG510
3. Run the LISTA software.
Installation and Operation
Make a directory like C:LISTA and copy the all files in the floppy disk of
VFK1420.
Type Lista50.exe in the DOS mode to run the LISTA software.
4. Select the model of AJ-D950 in the menu.
5. Select a alignment tape to use LISTA Adjustment. If it is not
displayed choose one of the listed tape and type Y ( (Y)es or (N)o)
and resist the data which is supplied with the alignment tape.
5.6.32. Alignment Tape Data Registration
1. Select <4> Alignment Tape in the LISTA software main menu.
2. Select <2> ENTRY in the Alignment Tape Menu.
3. When << Alignment tape Data Entry >> is displayed, input the tape
serial number according with the menu instruction. The serial
number is stumped on the alignment tape. Then select the PAL or
NTSC. Type 0 or ENTER to choose DVCPRO.
TP732 ATF ERR (SERVO:F1)
TP722 R/P HSW (SERVO:F1)
TP723 PB HSW (SERVO:F1)
TG510 GND (SERVO:F1)
PC (AD Board must be installed.), Oscilloscope
VFM3580KM (ENV LEVEL), VFM3581KM (LISTA)
VFK1420 (LISTA Software), VFK1186(LISTA Cable)