Siemens Sinumerik 840D sl Function Manual page 782

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Diagnostics
10.3 Safety messages for SINAMICS S120
C01798
Response
Acknowledgment
Explanation
Remedy
C01799
Response
Acknowledgment
Explanation
Remedy
List of faults and alarms (Motor Module)
F30600
Response
Acknowledgment
Explanation
10-782
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
SI Motion P1 (CU): Test stop running
NONE
IMMEDIATELY (POWER ON)
The test stop is active.
Not necessary.
The message is withdrawn when the test stop is completed.
SI Motion P1 (CU): Acceptance test mode active
NONE
IMMEDIATELY (POWER ON)
The acceptance test mode is active.
The following applies to safety functions with SINUMERIK:
The power on messages of the safe motion monitoring functions can
be acknowledged during the acceptance test using the acknowledg-
ment options of the higher--level control.
Not necessary.
The message is withdrawn when exiting the acceptance test mode.
SI P2: STOP A initiated
OFF2
IMMEDIATELY (POWER ON)
The "Safety Integrated" function integrated in the drive on monitoring
channel to has detected a fault and initiated a STOP A (STO via the
safety shutdown path of monitoring channel 2).
-- Forced checking procedure of the safety shutdown path of the
monitoring channel unsuccessful.
-- Subsequent response to fault F30611 (defect in a monitoring
channel).
Fault value (r0949, interpret decimal):
0:
Stop request from the Control Unit
1005: STO active, although STO not selected and there is no internal STOP
A present.
1010: STO inactive although STO is selected or an internal STOP A is
present.
1011: Internal error for STO deselected in monitoring channel 2.
1020: Internal software error in the "Internal voltage protection" function.
The "Internal voltage protection" function is cancelled. A STOP A that
cannot be acknowledged is initiated.
9999: Subsequent response to fault F30611
© Siemens AG 2015 All Rights Reserved