Diagnostics
10.2 NCK safety alarms for Sinumerik 840D sl
27204
Parameter
Explanation
Response
Remedy
Program
r
continuation
27205
Parameter
Explanation
Response
Remedy
Program
r
continuation
10-718
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
PROFIsafe: Double assignment MD %1[%2] - - MD %3[%4]
%1 = MD name 1
%2 = MD field index for MD name 1
%3 = MD name 2
%4 = MD field index for MD name 2
A double assignment has been illegally parameterized in the specified
machine data.
Several input terminals of PROFIsafe modules parameterized at the
same $A_INSE. MD involved:
-- MD10388 $MN_PROFISAFE_IN_ASSIGN
Several $A_OUTSE parameterized at the same output of a PROFIsafe
module. MD involved:
-- MD13301 $MN_PROFISAFE_OUT_FILTER
Several substitute values of passive SPL couplings parameterized to
the same $A_INSE. MD involved:
-- MD10388 $MN_PROFISAFE_IN_ASSIGN
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Correct the displayed MD.
The alarm is initiated when booting. No program can be started. Only
clear the alarm with POWER ON.
PROFIsafe: Number of signals
%1 MD name 1
%2 MD field index to the MD name 1
%3 MD name 2
%4 MD field index to the MD name 2
The parameterized number of signals used must be the same in both
machine data.
Mode group not ready
Channel not ready
NC start disable in this channel
Interface signals are set
Alarm display
NC stop for alarm
Correct the specified MD.
The alarm is initiated when booting. No program can be started. Only
clear the alarm with POWER ON.
in
MD %1[%2] < > MD %3[%4]
© Siemens AG 2015 All Rights Reserved