10/15
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
58
There is a difference in the active request for an external STOP. Two
factors determine the resulting external STOP request for a monitoring
channel.
S The STOP requested via the SGE interface
S The STOP passed--through from the other monitoring channel
The STOP of the active request is specified as fine error code for the
NCK and drive.
The following values are possible:
0 = No Stop
2 = Stop E
3 = Stop D
4 = Stop C
7 = Stop A
59
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[0] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
60
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[1] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
61
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[2] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
62
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[3] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
63
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[4] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
64
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[5] does
not correspond with the associated drive parameter assignment.
Remedy
Copy SI data.
65
The setting in MD36932 $MA_SAFE_VELO_OVR_FACTOR[6] does
not correspond with the associated drive parameter assignment.
10.2NCK safety alarms for Sinumerik 840D sl