10/15
Table 8-9
Overview of system variables, continued
F_RECVDP
Inputs
$A_FRDP_SUBS[
The substitute values that are
n]
output to the SPL in certain states
are entered
$A_FRDP_ERR_R
Response when a communication
EAC[n]
error occurs
$A_FRDP_ACK_R
Error- -free F telegrams are again
EI[n]
cyclically exchanged after a com-
munication error
Outputs
$A_FRDP_ER-
There is a communication error
ROR[n]
$A_FRDP_SUBS_
Substitute values are output to the
ON[n]
application
$A_FRDP_ACK_R
Error- -free F telegrams are again
EQ[n]
cyclically exchanged after a com-
munication error
$A_FRDP_SEND-
Actual operating mode of the
MODE[n]
F- -CPU of the F_SENDDP com-
munication partner
$A_FRDP_DIAG[n
The cause of the communication
error determined by F_RECVDP
]
is communicated
© Siemens AG 2015 All Rights Reserved
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
n = 1, ..., 16
INT
stands for the
number of the
F- -RECVDP
relationship, is
also valid for
$A_FRDP_
ERR_REAC,
$A_FRDP_
ACK_REI,
$A_FRDP_
ERROR,
$A_FRDP_
SUBS_ON,
$A_FRDP_
ACK_REQ,
$A_FRDP_
SENDMODE,
$A_FRDP_
DIAG
n = 1, ..., 16
INT
n = 1, ..., 16
BOOL
n = 1, ..., 16
BOOL
n = 1, ..., 16
BOOL
n = 1, ..., 16
BOOL
n = 1, ..., 16
BOOL
n = 1, ..., 16
INT
Data Description
8.7 System variables
r
w
r
w
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x