Siemens Sinumerik 840D sl Function Manual page 382

Sinumerik safety integrated
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

Data Description
8.1 Machine data for SINUMERIK 840D sl
13372
MD number
Default value 1008, 992, 976, 960, 944,
928, 912, 896, 880, 864, 848, 832,
816, 800, 784, 768, 752, 736, 720, 704,
688, 672, 656, 640, 624, 608, 592, 576,
560, 544, 528, 512, 496, 480, 464, 448,
432, 416, 400, 384, 368, 352
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
Additional references
MD13372 $MN_PS_DRIVE_LOGIC_ADDR is not relevant for this documentation.
13374
MD number
Default value 5800, 5816, 5832, 5848,
5864, 5880, 5896, 5912, 5928, 5944,
5960, 5976, 5992, 6008, 6024, 6040,
6056, 6072, 6088, 6104, 6120, 6136,
6152, 6168, 6184, 6200, 6216, 6232,
6248, 6264, 6280
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
13376
MD number
Default value 701
Change becomes effective after: POWER ON
Data type: DWORD
Meaning:
corresponds with ...
8-382
SINUMERIK 840D sl/SINAMICS S120 SINUMERIK Safety Integrated (FBSI sl) - - 10.2015 Edition
$MN_PS_DRIVE_LOGIC_ADDR[0...30]
Logical PROFIsafe drive address SI
Min. input limit: 0
Protection level: 7/2
The default values of the logical basis addresses correspond to the values from the S7
default configuration.
$MN_SAFE_INFO_DRIVE_LOGIC_ADDR[0...30]
Logical SIC/SCC drive address SI
Min. input limit: 0
Protection level: 7/2
Logical basis addresses for the SIC/SCC communication between NCK and drive
The default values of the logical basis addresses correspond to the values from the S7
default configuration.
$MC_SAFE_INFO_TELEGRAM_TYPE[0...30]
SIC/SCC telegram number
Min. input limit: 0
Protection level: 7/2
Number of the SIC/SCC telegram type
Max. input limit: 16383
Unit: - -
Max. input limit: 16383
Unit: - -
Max. input limit: 999
Unit: - -
© Siemens AG 2015 All Rights Reserved